EWPA 007 4-20mA 0,5 8 BAR IP54 ¼ SAE MALE 2m cable - Eliwell TD220007
Pressure Transducer 4-20 mA
Code de produit: TD220007
          
                        €110,60
                      
                      
                        
                          Tva exclue
                        
                    Indisponible
| Operating Temperature | -40...100 | 
| Storage Temperature | -40...100 | 
| Power Supply | 8…32V | 
| Operating Range | -0,5…7,0 bar ( relative ) | 
| Output Signal | 2 wires 4…20mA | 
| Overload | 2 times pressure range | 
| Compensated temperature | 0…+50°C | 
| Electrical connections | 2m cable wired | 
| Mechanical connections | male connector, 14 SAE (716" -20UNF) | 
| Global error at T 0…50°C | max ± 1,0% FS | 
| Global error at T -10…80°C | max ± 1,5% FS | 
| Response time | (0…99%) <5ms | 
| Material in contact with the environment | AISI 316L Viton outer seal | 
| Enclosure rating | 
			 IP54  | 
		
| 
			 Weight (g) Net  | 
			170 | 
| Width (L) Net | 22 | 
| Height (Ht) Net | 22 | 
| Depth (P) Net | 53 | 
| Weight (g) Packaging | 200 | 
| Width (L) Packaging | 130 | 
| Height (Ht) Packaging | 90 | 
| Depth (P) Packaging | 50 | 

                
						
						
						
						
      
      
    
      